Changes for page Sensors

Last modified by Андрей Калиновский on 2023/04/26 11:18

<
From version < 47.1 >
edited by Андрей Калиновский
on 2023/04/25 14:13
To version < 50.1 >
edited by Андрей Калиновский
on 2023/04/26 11:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,7 @@
1 -Below is a description of the "Sensors" tab, detailed examples of work [[are published here.>>doc:.Примеры заведения датчиков.WebHome]]
1 +Below is a description of the "Sensors" tab, detailed examples of work are published here.
2 2  \\
3 3  
4 -{{video url="https://youtu.be/C50F-Ieyix4" width="50%"/}}
4 +{{video url="https://www.youtube.com/watch?v=IvSDm5ziA7k&list=PLnkd3b-WBcpHWYhylpHeysMaTpqLc4Tlm&index=2" width="50%"/}}
5 5  
6 6  
7 7  (% class="box warningmessage" %)
... ... @@ -16,15 +16,15 @@
16 16  
17 17  It is also possible to export the created sensors or import them using the Import/Export button.
18 18  
19 -[[image:image-20220519164727-4.png]]
19 +[[image:image-20230425141320-1.png]]
20 20  
21 21  When exporting sensors, you can select a list of sensors and the need to upload their calibration tables and event templates to a *.csv file.
22 22  
23 -[[image:image-20220519164727-5.png]]
23 +[[image:image-20230425141334-2.png]]
24 24  
25 25  When importing, you can also make a similar selection.
26 26  
27 -[[image:image-20220519164727-6.png]]
27 +[[image:image-20230425141339-3.png]]
28 28  
29 29  
30 30  The created sensors are shown in a table with the following columns:
... ... @@ -39,7 +39,7 @@
39 39  
40 40  [[image:image-20220519164727-7.png]] **//sensor activity//** - activates/deactivates the sensor. In the off state, the sensor does not participate in event detection and other calculations for the object.
41 41  
42 -[[image:image-20220519164727-8.png]]
42 +[[image:image-20230425141356-6.png]]
43 43  
44 44  
45 45  Button [[image:image-20220519164727-9.png]]"Add" is designed to add a new sensor to the object.
... ... @@ -49,12 +49,12 @@
49 49  
50 50  **Type** – selection of sensor connection type (simple/virtual). The simple type is used when entering physical sensors that are displayed in the dashboard as unregistered sensors or in the navigation report as non-calibrated.
51 51  
52 -[[image:image-20220519164727-10.png]]
52 +[[image:image-20230425141346-4.png]]
53 53  
54 54  The virtual sensor connection type allows you to create a sensor that uses other sensors. When selected, the "Function" field opens.
55 55  
56 56  
57 -{{video url="https://youtu.be/T3alpKIQ4cE" width="50%"/}}
57 +{{video url="https://www.youtube.com/watch?v=c3DnKXC4Cto&list=PLnkd3b-WBcpHWYhylpHeysMaTpqLc4Tlm&index=3" width="50%"/}}
58 58  
59 59  
60 60  **Alias** ​​– set variable for special formulas of the virtual sensor, using the current sensor;
... ... @@ -66,7 +66,7 @@
66 66  **//Ignition //** - a sensor that indicates whether the ignition is on or off. Used in event templates "Engine operation", "Idling", "Stop", "Random sensor operation";
67 67  
68 68  
69 -{{video url="https://youtu.be/U0t3o7tMrME" width="50%"/}}
69 +{{video url="https://www.youtube.com/watch?v=b7Msds_E24E&list=PLnkd3b-WBcpHWYhylpHeysMaTpqLc4Tlm&index=4" width="50%"/}}
70 70  
71 71  
72 72  **//Panic button//** - a sensor that indicates the operation of the panic button (SOS). Used in the "Alarm" event template;
... ... @@ -85,7 +85,7 @@
85 85  
86 86  **//Relative engine hours//** - a sensor that allows you to calculate the engine hours of a vehicle relative to the coefficient, more details in the article[[ Relative engine hours>>https://wiki.glonasssoft.ru/bin/view/%D0%9F%D0%B0%D0%BD%D0%B5%D0%BB%D1%8C%20%D1%83%D0%BF%D1%80%D0%B0%D0%B2%D0%BB%D0%B5%D0%BD%D0%B8%D1%8F/%D0%A0%D0%B0%D0%B7%D0%B4%D0%B5%D0%BB%20%22%D0%9E%D0%B1%D1%8A%D0%B5%D0%BA%D1%82%D1%8B%22/%D0%94%D0%B0%D1%82%D1%87%D0%B8%D0%BA%D0%B8/%D0%9E%D1%82%D0%BD%D0%BE%D1%81%D0%B8%D1%82%D0%B5%D0%BB%D1%8C%D0%BD%D1%8B%D0%B5%20%D0%BC%D0%BE%D1%82%D0%BE%D1%87%D0%B0%D1%81%D1%8B/]] . If a sensor with this type is created, then Engine hours both in reports and in Norms are calculated taking into account this sensor;
87 87  
88 -//**Mileage sensor**// - this sensor allows you to replace the mileage calculated according to GPS data with the mileage transmitted from the on-board computer of the car. After creating the sensor, you must specify** the Mileage calculation** parameter[[** in the Norms **>>https://wiki.glonasssoft.ru/bin/view/%D0%9F%D0%B0%D0%BD%D0%B5%D0%BB%D1%8C%20%D1%83%D0%BF%D1%80%D0%B0%D0%B2%D0%BB%D0%B5%D0%BD%D0%B8%D1%8F/%D0%A0%D0%B0%D0%B7%D0%B4%D0%B5%D0%BB%20%22%D0%9E%D0%B1%D1%8A%D0%B5%D0%BA%D1%82%D1%8B%22/%D0%9D%D0%BE%D1%80%D0%BC%D1%8B/#]] as** Mileage sensor** .[[ >>https://wiki.glonasssoft.ru/bin/view/%D0%9F%D0%B0%D0%BD%D0%B5%D0%BB%D1%8C%20%D1%83%D0%BF%D1%80%D0%B0%D0%B2%D0%BB%D0%B5%D0%BD%D0%B8%D1%8F/%D0%A0%D0%B0%D0%B7%D0%B4%D0%B5%D0%BB%20%22%D0%9E%D0%B1%D1%8A%D0%B5%D0%BA%D1%82%D1%8B%22/%D0%9D%D0%BE%D1%80%D0%BC%D1%8B/#]]
88 +//**Mileage sensor**// - this sensor allows you to replace the mileage calculated according to GPS data with the mileage transmitted from the on-board computer of the car. After creating the sensor, you must specify** the Mileage calculation** parameter[[** in the Norms **>>https://enwiki.glonasssoft.ru/bin/view/%D0%9F%D0%B0%D0%BD%D0%B5%D0%BB%D1%8C%20%D1%83%D0%BF%D1%80%D0%B0%D0%B2%D0%BB%D0%B5%D0%BD%D0%B8%D1%8F/%D0%A0%D0%B0%D0%B7%D0%B4%D0%B5%D0%BB%20%22%D0%9E%D0%B1%D1%8A%D0%B5%D0%BA%D1%82%D1%8B%22/%D0%9D%D0%BE%D1%80%D0%BC%D1%8B/#]] as** Mileage sensor** .[[ >>https://wiki.glonasssoft.ru/bin/view/%D0%9F%D0%B0%D0%BD%D0%B5%D0%BB%D1%8C%20%D1%83%D0%BF%D1%80%D0%B0%D0%B2%D0%BB%D0%B5%D0%BD%D0%B8%D1%8F/%D0%A0%D0%B0%D0%B7%D0%B4%D0%B5%D0%BB%20%22%D0%9E%D0%B1%D1%8A%D0%B5%D0%BA%D1%82%D1%8B%22/%D0%9D%D0%BE%D1%80%D0%BC%D1%8B/#]]
89 89  
90 90  
91 91  ==== **Fuel** ====
... ... @@ -148,9 +148,6 @@
148 148  **//GNSS jamming sensor//** - allows you to determine the fact of GNSS signal jamming. Used in the "GNSS Jamming" event template;
149 149  
150 150  
151 -{{video url="https://youtu.be/8i1A0xIBBpc" width="50%"/}}
152 -
153 -
154 154  **//Custom sensor//** - a sensor that can be configured to measure any indicator. Depending on the settings, it can be used in the event templates "Operation of an arbitrary sensor" and "Number of triggers of an arbitrary sensor".
155 155  
156 156  
... ... @@ -163,10 +163,10 @@
163 163  
164 164  (% class="box infomessage" %)
165 165  (((
166 -**IMPORTANT! **//In GLONASSSoft CMT, the named parameters received from the terminal are converted into sensors (a combination of sensor type and input number) according to internal maps of correspondence - maps.
163 +**IMPORTANT! **//In GLONASSSoft CMT, the named parameters received from the terminal are converted into sensors (a combination of sensor type and input number) according to internal maps of correspondence - maps.
167 167  \\In the info panel of the object, you can see lines like~://
168 -\\Analog[100]: 1048640 (param1)
169 -\\//where "Analog" - input type, [100] - input number, 1048640 - parameter value, param1 - named parameter name.
165 +\\Analog[100]: 1048640 (param1)
166 +\\//where "Analog" - input type, [100] - input number, 1048640 - parameter value, param1 - named parameter name.
170 170  If there is no sensor displayed as a named parameter in the dashboard, we can add it upon request to technical support.//
171 171  )))
172 172  
... ... @@ -178,7 +178,7 @@
178 178  The aggregating function "expression" allows you to use a special formula in the field of the same name.
179 179  
180 180  
181 -**Formula** - the field becomes available when you select the sensor connection type "Virtual" and the aggregating function "expression". The reference book of functions and parameters of the virtual sensor with examples is available by clicking the button[[image:image-20220519164727-11.png]]or [[by link>>doc:Панель управления.Основные справочники.Справочник функций и параметров виртуального датчика.WebHome]]
178 +**Formula** - the field becomes available when you select the sensor connection type "Virtual" and the aggregating function "expression". The reference book of functions and parameters of the virtual sensor with examples is available by clicking the button[[image:image-20220519164727-11.png]]or by link
182 182  
183 183  
184 184  **Calibration type** – enables/disables sensor calibration. The list of available calibration types depends on the input type and sensor type.
... ... @@ -185,11 +185,11 @@
185 185  
186 186  **//By default//** - tare is not used;
187 187  
188 -**//On/Off//** - discrete sensor, below in** the Form** you can specify the text that will be displayed instead of** On. **or** Off. **;
185 +**//On/Off//** - discrete sensor, below in** the Form** you can specify the text that will be displayed instead of** On. **or** Off. **;
189 189  
190 190  **//Table//** - the output value is calculated in accordance with the calibration table, while the input parameters less than the first and greater than or equal to the last line are considered invalid and ignored. Thus, it is possible to cut off bursts / drops in the fuel level more / less than the maximum allowable;
191 191  
192 -**//Accumulator//** - converts the input parameters into an accumulated value. For sensors of this type, the calculation table is applied to the difference between two adjacent messages. Used for flow meters and signal pickup devices. Also, for this type of calibration, you can specify the maximum value of the parameter in the** Max. value** . In the case when the parameter value reaches the maximum and jumps, the system will correctly calculate the "zeroing" of the sensor;
189 +**//Accumulator//** - converts the input parameters into an accumulated value. For sensors of this type, the calculation table is applied to the difference between two adjacent messages. Used for flow meters and signal pickup devices. Also, for this type of calibration, you can specify the maximum value of the parameter in the** Max. value** . In the case when the parameter value reaches the maximum and jumps, the system will correctly calculate the "zeroing" of the sensor;
193 193  
194 194  **//The difference from before //** - also converts the input parameters to an accumulated value. Unlike the accumulator, it counts the input parameters since the previous measurement (message). For sensors of this type, the calculation table is applied to the difference between two adjacent messages. It is used for instantaneous flow sensors when the device transmits not the accumulated value of pulses, but the number of pulses between messages.
195 195  
image-20230425141356-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Gadmin
Size
... ... @@ -1,0 +1,1 @@
1 +14.0 KB
Content

Menu

GLONASSSoft wiki - 2023 г